International Environmental Technologies,
Inc.
The results shown for the WG/TO are the average emission levels measured in over 60+ tests run over the last 16 years.
|
Contaminant |
US EPA Standard* |
Avg. WG/TO Sys. Emissions | ||
|
Total Particulate Matter |
24 mg/m3 |
3.9 mg/m3 | ||
|
Carbon Monoxide |
50 ppm |
0-2 ppm | ||
|
Sulphur Dioxide |
30 ppm |
<2 ppm | ||
|
Hydrogen Chloride |
25 ppm |
0.01 ppm | ||
|
Nitric Oxide |
150 ppm |
33 ppm | ||
|
Dioxins and Furans |
13 ng/m3 |
0.553 ng/m3 | ||
|
Cadmium and Compounds |
0.020 mg/m3 |
<0.00001 mg/m3 | ||
|
Lead and Compounds |
0.20 mg/m3 |
0.00000806 mg/m3 | ||
|
Mercury and Compounds |
0.080 mg/m3 |
0.0000114 mg/m3 | ||
|
Heavy Metals |
--- |
0.0012 mg/m3 | ||
| *Taken from 40CFR Part 60 Subpart Eb - Standards of Performance for Municipal Waste Combustors for Which Construction is Commenced After September 20, 1994 | ||||